new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Mar 19

Verifying Good Regulator Conditions for Hypergraph Observers: Natural Gradient Learning from Causal Invariance via Established Theorems

We verify that persistent observers in causally invariant hypergraph substrates satisfy the conditions of the Conant-Ashby Good Regulator Theorem. Building on Wolfram's hypergraph physics and Vanchurin's neural network cosmology, we formalize persistent observers as entities that minimize prediction error at their boundary with the environment. Applying a modern reformulation of the Conant-Ashby theorem, we demonstrate that hypergraph observers satisfy Good Regulator conditions, requiring them to maintain internal models. Once an internal model with loss function exists, the emergence of a Fisher information metric follows from standard information geometry. Invoking Amari's uniqueness theorem for reparameterization-invariant gradients, we show that natural gradient descent is the unique admissible learning rule. Under the ansatz M=F^2 for exponential family observers and one specific convergence time functional, we derive a closed-form formula for the regime parameter alpha in Vanchurin's Type II framework, with a quantum-classical threshold at kappa(F)=2. However, three alternative convergence models do not reproduce this result, so this prediction is strongly model-dependent. We further introduce the directional regime parameter alpha_{v_k} and the trace-free deviation tensor, showing that a single observer can simultaneously occupy different Vanchurin regimes along different eigendirections of the Fisher metric. This connects Wolfram and Vanchurin frameworks through established theorems, providing approximately 25-30% novel contribution.

  • 1 authors
·
Mar 9

From Passive Observer to Active Critic: Reinforcement Learning Elicits Process Reasoning for Robotic Manipulation

Accurate process supervision remains a critical challenge for long-horizon robotic manipulation. A primary bottleneck is that current video MLLMs, trained primarily under a Supervised Fine-Tuning (SFT) paradigm, function as passive "Observers" that recognize ongoing events rather than evaluating the current state relative to the final task goal. In this paper, we introduce PRIMO R1 (Process Reasoning Induced Monitoring), a 7B framework that transforms video MLLMs into active "Critics". We leverage outcome-based Reinforcement Learning to incentivize explicit Chain-of-Thought generation for progress estimation. Furthermore, our architecture constructs a structured temporal input by explicitly anchoring the video sequence between initial and current state images. Supported by the proposed PRIMO Dataset and Benchmark, extensive experiments across diverse in-domain environments and out-of-domain real-world humanoid scenarios demonstrate that PRIMO R1 achieves state-of-the-art performance. Quantitatively, our 7B model achieves a 50% reduction in the mean absolute error of specialized reasoning baselines, demonstrating significant relative accuracy improvements over 72B-scale general MLLMs. Furthermore, PRIMO R1 exhibits strong zero-shot generalization on difficult failure detection tasks. We establish state-of-the-art performance on RoboFail benchmark with 67.0% accuracy, surpassing closed-source models like OpenAI o1 by 6.0%.

Deep learning automates Cobb angle measurement compared with multi-expert observers

Scoliosis, a prevalent condition characterized by abnormal spinal curvature leading to deformity, requires precise assessment methods for effective diagnosis and management. The Cobb angle is a widely used scoliosis quantification method that measures the degree of curvature between the tilted vertebrae. Yet, manual measuring of Cobb angles is time-consuming and labor-intensive, fraught with significant interobserver and intraobserver variability. To address these challenges and the lack of interpretability found in certain existing automated methods, we have created fully automated software that not only precisely measures the Cobb angle but also provides clear visualizations of these measurements. This software integrates deep neural network-based spine region detection and segmentation, spine centerline identification, pinpointing the most significantly tilted vertebrae, and direct visualization of Cobb angles on the original images. Upon comparison with the assessments of 7 expert readers, our algorithm exhibited a mean deviation in Cobb angle measurements of 4.17 degrees, notably surpassing the manual approach's average intra-reader discrepancy of 5.16 degrees. The algorithm also achieved intra-class correlation coefficients (ICC) exceeding 0.96 and Pearson correlation coefficients above 0.944, reflecting robust agreement with expert assessments and superior measurement reliability. Through the comprehensive reader study and statistical analysis, we believe this algorithm not only ensures a higher consensus with expert readers but also enhances interpretability and reproducibility during assessments. It holds significant promise for clinical application, potentially aiding physicians in more accurate scoliosis assessment and diagnosis, thereby improving patient care.

  • 14 authors
·
Mar 18, 2024

Development and evaluation of intraoperative ultrasound segmentation with negative image frames and multiple observer labels

When developing deep neural networks for segmenting intraoperative ultrasound images, several practical issues are encountered frequently, such as the presence of ultrasound frames that do not contain regions of interest and the high variance in ground-truth labels. In this study, we evaluate the utility of a pre-screening classification network prior to the segmentation network. Experimental results demonstrate that such a classifier, minimising frame classification errors, was able to directly impact the number of false positive and false negative frames. Importantly, the segmentation accuracy on the classifier-selected frames, that would be segmented, remains comparable to or better than those from standalone segmentation networks. Interestingly, the efficacy of the pre-screening classifier was affected by the sampling methods for training labels from multiple observers, a seemingly independent problem. We show experimentally that a previously proposed approach, combining random sampling and consensus labels, may need to be adapted to perform well in our application. Furthermore, this work aims to share practical experience in developing a machine learning application that assists highly variable interventional imaging for prostate cancer patients, to present robust and reproducible open-source implementations, and to report a set of comprehensive results and analysis comparing these practical, yet important, options in a real-world clinical application.

  • 11 authors
·
Jul 28, 2021